ASTM D-7698 1 / 16 1) 12. What is minimum required information in the final report A. All B. Test Number C. Name of Operators D. Location of Test 2 / 16 2) 16. The operating temperature range where the CIMI has been used globally is for the CIMI is between................ A. 34 F and 122 F B. None C. 56 F and 130 F D. 120 F and 180 F 3 / 16 3) 14. What is the role of Soil model and Testing process A. To correlate Physical properties with electrical measurements B. Soil Temperature C. Soil PH test D. to predict soil behavior 4 / 16 4) 6. The sample should be of sufficient amount of soil for at least ......................compaction specimens A. 6 B. 3 C. 4 D. 5 5 / 16 5) 3. All electrical values are equilibrated to............. A. 15.60 C B. 100.58 C C. None D. 15.55 C 6 / 16 6) 9. Standard Test Method for.............of Soil and Aggregate by Correlation with A. Soil PH B. In-Place Estimation of Density and Water Content C. Soil Temperature D. Analyze Soil particle size 7 / 16 7) 13. Calculate the sand equivalent to the nearest............ A. All B. 2% C. 1% D. 0.1% 8 / 16 8) 10. What is Required Before Testing a Job Site According to ASTM D 7698 A. None B. Soil PH C. Soil Temperature Measurement D. Creation of Soil model 9 / 16 9) Standard Test Method for In-Place Estimation of Density and Water Content of Soil and Aggregate by Correlation with........... A. All B. Nuclear Gauge C. Sand cone method D. Complex impedance metho 10 / 16 10) 11. How many Test Spots should be Used during Calibration procedure A. 6 B. 4 C. 10 D. 8 11 / 16 11) 2. Two major electrical properties of Soil................and..................Which are used to get complex-impedance A. Conductivity and resistivity B. None C. Conductivity values and relative dielectric permittivity D. Water content and depth 12 / 16 12) 8. Name of Instrument Used in ASTM D 7698 A. Electronic density Gauge EDG B. None C. Nuclear Gauge D. Sand Cone 13 / 16 13) 15. ASTM D 7698 method is useful for the .....................materials A. Porous material used in roads and Foundations B. Organic materials C. Granular material only D. Non-porous materials 14 / 16 14) 7. Typically amount of the sample should be A. 50 Kgs B. None C. 30 Kgs D. 20 Kgs 15 / 16 15) 5. Diameters of the Prob are A. Both B. 6.35 mm to 12.7 mm C. 5.35 mm to 12.9 mm D. None 16 / 16 16) 4. The length of soil electrical probes lengths between A. 101.6 to 304.8 B. 120.6 to 304.8 C. 101.6 to 250.8 mm D. None Loading your result Your score isThe average score is 0% 0% Restart quiz