ASTM C-1064

1 / 26

1. The technician must dampen the sample container with water prior to sampling of concrete

2 / 26

2. Complete the temperature measurement of freshly mixed concrete within................After obtaining the sample

3 / 26

3. A maximum temperature of freshly mixed concrete is specified in ASTM C 1064.

4 / 26

4. The calibration of temperature measuring device shall be performed by comparing the readings off the temperature measuring device at two temperature at least :

5 / 26

5. The sample of concrete used for temperature determination must be rodded 25 time

6 / 26

6. The temperature measuring device shall be calibrated

7 / 26

7. How long must the temperature measuring device remain in the freshly mixed concrete for an accurate reading ?

8 / 26

8. The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to ±.................degrees F(±............degrees C) throughout a range of..............to................degress

9 / 26

9. It is not acceptable to measure the temperature of freshly mixed concrete in the transporting equipment or the forms after discharge.

10 / 26

10. Concrete containing aggregate of a nominal maximum size of greater than 3 in. (75 mm) may require up to 20 min for transfer of heat from aggregate to mortar.

11 / 26

11. Assuming the coarse aggregate size is less than 3 inches. complete the temperature test within .................minutes after obtaining the sample

12 / 26

12. What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete?

13 / 26

13. According to ASTM C 1064, What is one reason to take the temperature of concrete ?

14 / 26

14. Leave the temperature measuring device in the freshly mixed concrete for a minimum period off ..................min or until the temperature reading stabilizes.

15 / 26

15. A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature.

16 / 26

16. The sensor of the temperature measuring device shall have at least........in(...........mm) of concrete cover in all direction

17 / 26

17. The temperature of freshly mixed concrete can be measured in :

18 / 26

18. The concrete cover in the container must be at least three times the nominal maximum size the coarse aggregate

19 / 26

19. What special procedures are required when taking the temperature of concrete containing large size coarse aggregate ( Over 3 in (75 mm)

20 / 26

20. The reference temperature measuring device shall be readable and accurate to...............

21 / 26

21. When determining the temperature of fresh concrete, What is the minimum amount of concrete cover in all directions around the sensor of the temperature measuring device ?

22 / 26

22. Partial immersion liquid in glass thermometer shall have a permanent mark to which the device must be immersed without applying a correction factor.

23 / 26

23. Gently press concrete around the temperature measuring device so that..............does not affect the reading.

24 / 26

24. The temperature of concrete may be measured in a wheelbarrow

25 / 26

25. The temperature of concrete may be measured in a wall form ?

26 / 26

26. The temperature of the concrete is recorded to the nearest ;