ASTM C-1064

1 / 26

1. The temperature of concrete may be measured in a wall form ?

2 / 26

2. The concrete cover in the container must be at least three times the nominal maximum size the coarse aggregate

3 / 26

3. The temperature measuring device shall be calibrated

4 / 26

4. The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to ±.................degrees F(±............degrees C) throughout a range of..............to................degress

5 / 26

5. The temperature of concrete may be measured in a wheelbarrow

6 / 26

6. How long must the temperature measuring device remain in the freshly mixed concrete for an accurate reading ?

7 / 26

7. The sample of concrete used for temperature determination must be rodded 25 time

8 / 26

8. The reference temperature measuring device shall be readable and accurate to...............

9 / 26

9. What special procedures are required when taking the temperature of concrete containing large size coarse aggregate ( Over 3 in (75 mm)

10 / 26

10. A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature.

11 / 26

11. The calibration of temperature measuring device shall be performed by comparing the readings off the temperature measuring device at two temperature at least :

12 / 26

12. The temperature of freshly mixed concrete can be measured in :

13 / 26

13. Concrete containing aggregate of a nominal maximum size of greater than 3 in. (75 mm) may require up to 20 min for transfer of heat from aggregate to mortar.

14 / 26

14. When determining the temperature of fresh concrete, What is the minimum amount of concrete cover in all directions around the sensor of the temperature measuring device ?

15 / 26

15. What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete?

16 / 26

16. A maximum temperature of freshly mixed concrete is specified in ASTM C 1064.

17 / 26

17. Complete the temperature measurement of freshly mixed concrete within................After obtaining the sample

18 / 26

18. Gently press concrete around the temperature measuring device so that..............does not affect the reading.

19 / 26

19. It is not acceptable to measure the temperature of freshly mixed concrete in the transporting equipment or the forms after discharge.

20 / 26

20. Assuming the coarse aggregate size is less than 3 inches. complete the temperature test within .................minutes after obtaining the sample

21 / 26

21. According to ASTM C 1064, What is one reason to take the temperature of concrete ?

22 / 26

22. Leave the temperature measuring device in the freshly mixed concrete for a minimum period off ..................min or until the temperature reading stabilizes.

23 / 26

23. The temperature of the concrete is recorded to the nearest ;

24 / 26

24. The sensor of the temperature measuring device shall have at least........in(...........mm) of concrete cover in all direction

25 / 26

25. Partial immersion liquid in glass thermometer shall have a permanent mark to which the device must be immersed without applying a correction factor.

26 / 26

26. The technician must dampen the sample container with water prior to sampling of concrete